-40%

100mm CM310 Solder Pot Bath 300W Lead-Free Titanium Alloy Round Soldering Irons

$ 59.05

Availability: 100 in stock
  • Condition: New
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • MPN: Does Not Apply
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Return shipping will be paid by: Buyer
  • Brand: Unbranded

    Description

    New Solder Pot Bath CM310 300W Lead-Free Titanium Alloy Round Soldering Irons
    NOTE: we don't ship the item to PO BOX address, and we only ship the item to the address written in English,
    so please leave us your physical English address when you pay.
    If your country is not listed in our shipping policy, pls tell us your city and zip code, we will check whether your city belong to remote area or not, then tell you the accurate freight.Tks for your understanding and coopearation.
    please select the voltage 110v or 220v you need, or we'll select one for you according to your country.
    Rated power
    300W
    Temperature range
    50-480

    Melting tin quantity
    2.2kg
    Frequency
    50-60Hz
    (mm)
    Tin pot diameter
    100
    1, the working voltage: AC220 ± 10V (can be customized 110V)
    2, Operating temperature: 0 - 55 degrees
    3, the working temperature: <90% RH non-condensing
    Methods of operation and function setting:
    1, the temperature setting:
    (1), open the furnace power switch, the operator panel displays the temperature measurements 3.0.0 Temperature setpoint 2.8.0.0, plus direct use + or minus - keys to adjust the temperature setting, press the plus + or minus - button will increase or decrease one unit, long press + plus or minus - keys continuously increase or decrease the temperature set value is automatically set after long-term storage in two seconds, not switch, power influence.
    (2) to open the tin stove power, the control panel displays the temperature measurements 3.0.0 Temperature setpoint 2.8.0.0., Type * use the shift key to adjust the temperature setpoint, which numbers behind the decimal point to stop in, you can use this number plus + or minus - keys to adjust. The set temperature is automatically set after long-term storage in two seconds, not switch, power influence.
    2, microcomputer auto-tuning:
    If the temperature measurements and temperature setpoint deviation too high (3-5 degrees), or when the temperature measurements and the actual oven temperature deviation is too high (10-20 degrees). Perform the auto-tuning operation, press and hold the shift key * three seconds thermostat will automatically enter the self-tuning state, the display and the set temperature AT, and two subtitle will not stop cross flashing, direct 20 minutes -40 minutes self-tuning at the end, only the normal display temperature you set. When self-tuning is not the end, if you want to quit and then press and hold the Shift key until the blinking stops * can be. Factory parameters is optimized values, generally do not have self-tuning.
    3, temperature compensation:
    If the temperature measurements and the actual oven temperature after the auto-tuning or deviation is too high, you can use the following method of correction.
    (1), hold down the CAL function key for two seconds to display the temperature measurements 5c at this temperature setpoint 0.0 press + or - to compensate. Compensation is completed, press CAL function key twice to save and exit.
    Example: measured temperature value than the actual oven temperature by 10 degrees, with a minus - keys to adjust to the temperature measurements 5c temperature settings -10, then press the function key CAL to save and exit. In contrast, the measured temperature value than the actual oven temperature by 10 degrees, with a plus + to adjust to the temperature measurements 5c 10 temperature settings, then press the function key CAL to save and exit.
    (2) factory parameter values. Press and hold the CAL function key for two seconds, the display 5c 0.0, and then press the function key
    CAL display Loc c, press the function key CAL, back to normal window, 5c that the compensation value.
    Loc represents lock, unlock representation.
    4 Note:
    (1), self-tuning, the other parameters can not be adjusted. ,
    (2), self-tuning needs 20-40 minutes after the end of the auto-tuning process also needs a stable 10-20 minutes, during which time fluctuated temperatures are normal.
    Shipping Policy
    We will send out the item within 2-3 days through DHL/EMS/FEDEX /UPS/SPEEDPAK/CHINA POST to the below countries:
    Belgium, Netherlands, Luxembourg, Italy, Germany, France, United Kingdom, San Marino;
    Austria ,Denmark ,Finland ,Greece ,Ireland ,GUERNSEY ,JERSEY ,Norway ,
    Portugal , spain , Sweden , Switzerland;
    Bulgaria,Cyprus,Estonia,Latvia,Lithuania,Malta,slovakia,slovenia;
    Czech Republic, Hungary, Poland, Romania,.
    Australia ,New Zealand ,Korea South, Malaysia, Thailand, Philippines ,Singapore , Bruniei ,Taiwan , Macau, Indonesia,
    USA, Canada
    We will send tracking number to your eBay email within 1 day after sending out your item
    We will mark the item at the very low value, so that you do not need to pay for the tax or pay a little tax.
    Payment policy:
    We accept Paypal only.
    Payments must be finished within 5 working days after bid, otherwise, Unpaid Item dispute will be reported to eBay.
    Refund &Return policy
    We take all the responsibility during delivery. If you do not receive your item, we will refund you the full money or send you a new item according to your request.
    We can accept the return item within 60 days after the buyer receives it. Once we receive the return item, then we will refund you full money.
    Feedback Policy
    We will very appreciate you give us positive feedback
    ASAP.  If the item you got in any problem, PLS don’t hesitates to contact us.  We will do our best to help solve the problem
    Powered by SoldEazy