New Solder Pot Bath CM310 300W Lead-Free Titanium Alloy Round Soldering IronsNOTE: we don't ship the item to PO BOX address, and we only ship the item to the address written in English,
so please leave us your physical English address when you pay.
If your country is not listed in our shipping policy, pls tell us your city and zip code, we will check whether your city belong to remote area or not, then tell you the accurate freight.Tks for your understanding and coopearation.
please select the voltage 110v or 220v you need, or we'll select one for you according to your country.
(mm)
Tin pot diameter
100
Rated power
300W
Temperature range
50-480
℃
Melting tin quantity
2.2kg
Frequency
50-60Hz
1, the working voltage: AC220 ± 10V (can be customized 110V)
2, Operating temperature: 0 - 55 degrees
3, the working temperature: <90% RH non-condensing
Methods of operation and function setting:
1, the temperature setting:
(1), open the furnace power switch, the operator panel displays the temperature measurements 3.0.0 Temperature setpoint 2.8.0.0, plus direct use + or minus - keys to adjust the temperature setting, press the plus + or minus - button will increase or decrease one unit, long press + plus or minus - keys continuously increase or decrease the temperature set value is automatically set after long-term storage in two seconds, not switch, power influence.
(2) to open the tin stove power, the control panel displays the temperature measurements 3.0.0 Temperature setpoint 2.8.0.0., Type * use the shift key to adjust the temperature setpoint, which numbers behind the decimal point to stop in, you can use this number plus + or minus - keys to adjust. The set temperature is automatically set after long-term storage in two seconds, not switch, power influence.
2, microcomputer auto-tuning:
If the temperature measurements and temperature setpoint deviation too high (3-5 degrees), or when the temperature measurements and the actual oven temperature deviation is too high (10-20 degrees). Perform the auto-tuning operation, press and hold the shift key * three seconds thermostat will automatically enter the self-tuning state, the display and the set temperature AT, and two subtitle will not stop cross flashing, direct 20 minutes -40 minutes self-tuning at the end, only the normal display temperature you set. When self-tuning is not the end, if you want to quit and then press and hold the Shift key until the blinking stops * can be. Factory parameters is optimized values, generally do not have self-tuning.
3, temperature compensation:
If the temperature measurements and the actual oven temperature after the auto-tuning or deviation is too high, you can use the following method of correction.
(1), hold down the CAL function key for two seconds to display the temperature measurements 5c at this temperature setpoint 0.0 press + or - to compensate. Compensation is completed, press CAL function key twice to save and exit.
Example: measured temperature value than the actual oven temperature by 10 degrees, with a minus - keys to adjust to the temperature measurements 5c temperature settings -10, then press the function key CAL to save and exit. In contrast, the measured temperature value than the actual oven temperature by 10 degrees, with a plus + to adjust to the temperature measurements 5c 10 temperature settings, then press the function key CAL to save and exit.
(2) factory parameter values. Press and hold the CAL function key for two seconds, the display 5c 0.0, and then press the function key
CAL display Loc c, press the function key CAL, back to normal window, 5c that the compensation value.
Loc represents lock, unlock representation.
4 Note:
(1), self-tuning, the other parameters can not be adjusted. ,
(2), self-tuning needs 20-40 minutes after the end of the auto-tuning process also needs a stable 10-20 minutes, during which time fluctuated temperatures are normal.